Seitenansicht 12
installing your dryer _13
ALCOVE OR CLOSET INSTALLATION
The dryer must be exhausted to the outside to reduce the risk of fi re when installed in an alcove or
closet.
No other fuel-burning appliance should be installed in the same closet as the dryer.
WARNING: To reduce the risk of fi re, this dryer must be exhausted to the outdoors.
See Exhaust information section.
MINIMUM CLEARANCES FOR CLOSET AND ALCOVE INSTALLATIONS:
Sides – 1 in / 25 mm
Rear – 4 in / 102 mm
Top – 17 in / 432 mm
Closet Front – 2 in / 51 mm
If the washer and dryer are installed together, the closet front must have at least a 72 in² (465 cm²)
unobstructed air opening.
A. Recessed area
B. Side view - closet or confi ned area
01 installing your dryer
1 in.
(2.5 cm)
1 in.
(2.5 cm)
1 in.
(2.5 cm)
27 in.
(68.6 cm)
27 in.
(68.6 cm)
A
2 in.
(5 cm)
4 in.
(10.2 cm)
34.1 in.
(86.5 cm)
17 in.
(43.2 cm)
B
WARNING