19Samsung Electronics
6-2 Trouble check in the initial status
6-2-1 Diagnosis and marking of the part in trouble.
Please check the air conditioner operation status and write the check result in the chart in the room.
6-2-2 Operation with abnormal motion
Indoor unit Temperature Sensor Error(SHORT/OPEN)
Indoor unit Piping Sensor Error(SHORT/OPEN)
EEPROM Error(Option Memory)
- Option Error
- Option Unselected
- Option Data Error
7-SEGMENT Mark Error Part
E1
E2
E6
All Lamp Off
No response from the
remote control opera-
tion signal.
Unable to operate the
outdoor unit
1) Plug out and plug in 5 seconds
later.
1) Press the TURBO button with the
remote control.
2) In 3 minutes, check the voltage
between the indoor unit terminal
block N and L.
Able to operate the
remote control
Unable to operate
the remote control
AC198V ~ AC242V
No power source
displayed.
OK
Press the AUTO button in the indoor
unit.
(1) If it operates, the remote control
and indoor unit receiver are in
trouble.
(2) If not, the indoor unit is in trouble.
Problem with the outdoor unit or PCB
Problem with the relay (RY71) or PCB
NO Abnormal condition Inspection Initial Diagnosis
1
2
The motor RPM is not sensible because the indoor fan motor has no feedback sensor.
Therefore, there is no fan motor error.
DB98-17813(1)_1 04/2/23 10:31 AM Page 19