INSTALLATION MANUAL
MANUAL DE INSTALACIÓN
MANUEL DINSTALLATION
MANUALE DINSTALLZIONE
MANUAL DE INSTALAÇÃO
INSTALLATIONS-HANDBUCH
E°XEIPI¢IO E°KATA™TA™H™
àçëíêìäñàü èé ìëíÄçéÇäÖ
System Air Conditioner
Aire acondicionado sistemático
Climatiseur numérique multifonctionnel
Sistema Aria Condizionata
Sistema Ar Condicionado
Klimaanlage System
™‡ÛÙËÌ· ∫ÏÈÌ·ÙÈÛÌÔ‡
ëËÒÚÂÏÌ˚È ÇÓÁ‰Û¯Ì˚È äÓ̉ˈËÓÌÂ
ESPAÑOL
FRANÇAIS
ITALIANO
PORTUGUÊS
DEUTSCH
E S F I P D G R DB98-05168A(2)
E§§HNIKA
RVMH050CBM0
RVMH060GBM0
RVMH060GDM0
RVMH080GAM0
RVMH100GAM0
RVMH100GCM0
RVMH100FAM0
Heat pump
RVMC035EBM0
RVMC050CBM0
RVMC060GAM0
RVMC060GAM1
RVMC070FAM0
RVMC100GAM0
RVMC100FAM0
Cooling only
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - Cooling only

RUSSIANENGLISHINSTALLATION MANUALMANUAL DE INSTALACIÓNMANUEL D’INSTALLATIONMANUALE D’INSTALLZIONEMANUAL DE INSTALAÇÃOINSTALLATIONS-HANDBUCHE°XEIPI¢IO

Seite 2 - Contents

Connecting the Cable (cont.)E-10Wiring Diagram of Power CableWhen using ELBs for 3 phase and 1 phaseWhen using an ELB for 3 phase 4 wiresMCCBELB ELBMC

Seite 3

E-11ENGLISHWiring Diagram of Connection CordConnection Cord SpecificationsIndoor Unit 1Outdoor UnitType A Outdoor unitIndoor Unit 2 Indoor Unit 3220V/

Seite 4 - How to choose Refnet Joint

Piping and refnet joint selectionE-12Outdoor unitOutdoor unitOutdoor unit112 2 2 3 3 3 4 4 55566 7 7 7 8 8 8614 11223344 5 5668877Outdoor unitOut

Seite 5 - 1m or more

E-13ENGLISHLimitation when piping is installed by using only Refnet joint(during 6 rooms installation)Outdoor unitab123456cdehgijkfH1H2Max. allowablel

Seite 6 - Unit : mm

E-14Piping and refnet joint selection (cont.)Requirement when piping is installed using simultaneously bothrefnet joint and contributor kit (during 6

Seite 7 - Outdoor Unit Installation

E-15ENGLISHInstall the oil trap◆ Install the oil trap in case that the outdoor unit is situated higher than theindoor unit.◆ Install the oil trap only

Seite 8 - Connecting the Cable

Connecting the Refrigerant PipeRefrigerant PipingThe refrigerant pipe can be connected from the bottom or front of the outdoor unit. You have to use s

Seite 9

Performing Leak Test & Vacuum DryingBefore completing the installation(insulation of the hose and piping),you must check that there are no gas lea

Seite 10 - Connecting the Cable (cont.)

Performing Leak Test & Vacuum Drying (cont.)◆ When you use the service port, always use a charging hose, too.◆ Check the leakage of refrigerant g

Seite 11

InsulationOnce you have checked that there are no leaks in the system, you caninsulate the piping and hose.To avoid condensation problems, place an in

Seite 12

Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33OOOOPPPPTTTTIIIIOOOONNNNAAAALLLLAAAACCCCCCCCEE

Seite 13 - (during 6 rooms installation)

Adding RefrigerantThe outdoor unit is loaded with sufficient refrigerant for the standard piping. Thus, refrigerant must be added if the piping is len

Seite 14 - Distributor kit

How to Calculate the Quantity of Adding RefrigerantOuter diameter of liquid refrigerant pipeQuantity of addingrefrigerant per metre6.35mm50g/m9.52mm80

Seite 15 - Piping selection

Adding Refrigerant (Cont.)‹A B C12 344000W4000W 2000W 2000W 2000W10000W6000W❋ Quantity of adding refrigerant= (Length of ø9.52 liquid pipe x 80g/m) +

Seite 16 - From the Front

◆Quantity of adding refrigerant = Total length of piping x quantity of adding refrigerant per metre◆Arrangement : Outer diameter of liquid refrigerant

Seite 17

Checking Correct GroundingIf the power distribution circuit does not have an earth or the ground doesnot comply with specifications, an grounding elec

Seite 18 - Using Stop Valve

Setting up Option SwitchesOutdoor Unit PCBYou should display that how many indoor units are connected tothe outdoor unit. Refer to the table below, th

Seite 19 - Insulation

Functions of KEY on the Outdoor Unit PCBKEY FunctionsE-26gSEG1afG1G2bcedSEG2gSEG3afG1G2bcedSEG4DisplayK1 K2 K3 K4KEYCheck mode RESET View modeFunction

Seite 20 - Balance Vacuum pump

Check ModeE-27ENGLISHView ModeIf you press KEY 4, the display shows you temperature and cycle dataaccording to number of times. Refer to the table bel

Seite 21 - 3200W 2000W 2000W

Checking and Testing OperationsE-28To complete the installation, perform the following checks and tests toensure that the air conditioner is operating

Seite 22 - Adding Refrigerant (Cont.)

E-29ENGLISHIf both sides numbers are equal, your computer will perform the nextstage.6Check the thermistor sensor, electronic expansion valve by using

Seite 23

E-3 Preparation for Outdoor Unit Installation . . . . . . . . . . 4 Deciding on where to Install the Outdoor Unit . . . . . . 5 Outdoor Unit In

Seite 24 - Checking Correct Grounding

TroubleshootingIf an error occurs during the operation, it is displayed on the outdoor unit PCB. E-30SEG 1, 2SEG 3, 4ExplanationDisplayHigh temperatur

Seite 25 - Rotary switch

E-31ENGLISHSEG 1, 2SEG 3, 4ExplanationDisplayBreakaway of indoor unit eva sensorBreakaway of indoor unit eva out sensorOpen error of electronic expans

Seite 26 - Check mode RESET View mode

Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33OOOOPPPPTTTTIIIIOOOONNNNAAAALLLLAAAACCCCCCCCEEEESSSSSSSSOOOORRRRIII

Seite 27 - View Mode

Parts ListE-33ENGLISHReceiver & Display Unit AccessoriesReceiver &display unit 1STS 2S-2x10tapped screw 42S-4x12tapped screw2Wire kit(leng

Seite 28 - How to Test Operations

Parts List (cont.)E-34Centralized Controller AccessoriesCentralizedcontroller 1Cable-tie 2Cable clamp5M4x16 tappedscrew7Wiredremote controller1Cable-

Seite 29

MemoE-35ENGLISH

Seite 30 - Troubleshooting

ELECTRONICSTHIS AIR CONDITIONER IS MANUFACTURED BY:ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:CE CLIMATISEUR EST FABRIQUE PAR:QUESTO CONDIZIONATORE

Seite 31

E-4Moving the Outdoor Unit by Wire RopeFasten the outdoor unit by two 8m or longer wire ropes asshown at the figure. To protect damage or scratches, i

Seite 32

Deciding on Where to Install the Outdoor UnitE-5ENGLISHOutdoor Unit◆ The outdoor unit must NEVER be placed on its side or upside down, as thecompresso

Seite 33 - Parts List

Deciding on Where to Install the Outdoor Unit (cont.)E-6If there is an obstacle around the outdoor unit...◆ If an obstacle in front of the outdoor uni

Seite 34 - Parts List (cont.)

Outdoor Unit InstallationE-7ENGLISHFix the outdoor unit with anchor bolts.◆The anchor bolt must be 20mm or higher from the basesurface.NNNNooootttteee

Seite 35

Outdoor Unit Installation (cont.)E-8◆ Make a drain outlet around the base for outdoor unitdrainage.◆ If the outdoor unit is installed on the roof, yo

Seite 36 - ELECTRONICS

Connecting the Cable (cont.)E-9ENGLISHPower Cable Specification❋ The power cable is not supplied with air conditioner.IMPORTANT : All power supply ca