6-7
Samsung Electronics
ALIGNMENT & ADJUSTMENTS
Service
Manual
6.1.2.6 HVPS Test Item : High Voltage Power Supply
- These Functions are used to check whether the control for HVPS is normal or not.
1. Press the "Menu Key", until finding "Developing Test" is displayed on the panel.
2. Press the "Select Key", when it's found.
3. Press the "Arrow keys" (< / >), until finding a suitable function
(Refer to the table below).
4. Press the "Select Key", when it's found.
5. Press the "Select Key" for execution or the "Cancel key" for stop.
Sub Menu Description Display (LCD) Remarks
Dev Bias Test Dev bias(- 470V) and Supply bias(- 650V) are Dev Bias On (Off)
supplied and after the execution key is chosen
and it stops when the stop key is chosen.
Charge Roll Charge roll voltage (- 1500V) is supplied after Charge: -1500V [Value] ADC value
Voltage Test the execution key is chosen and it stops when displayed
the stop key is chosen.
Transfer (+) Test Transfer positive voltage (+1000V) is supplied after Transfer: +1000V [Value ADC value
the execution key is chosen and it stops when displayed
the stop key is chosen.
Transfer (-) Test Transfer negative voltage(- 600 ~ -1000 V) is Transfer(-) On(Off) Voltage in
supplied after the execution key is chosen and it the range
stops when the stop key is chosen.
PTL Test PTL(Pre-Transfer Lamp) is on after the execution PTL On(Off)
key is chosen and it stops when the stop key
is chosen.
6.1.2.7 Developing Test Item : Fuser,Laser Scanning Unit
- These Functions are used to check whether functions related to the development are normal or not. (Fuser,
OPC, LSU)
1. Press the "Menu Key", until finding "Developing Test" is displayed on the panel.
2. Press the "Select Key", when it's found.
3. Press the "arrow keys" (< / >), until finding a suitable function
(Refer to the table below).
4. Press the "Select Key", when it's found.
5. Press the "Select Key" for execution or the "Cancel key" for stop.
Sub Menu Description Display (LCD) Remarks
Setting Temperature When Temp is displayed, Input a temperature [Temperature]:
Test
T:[target value]
you would like to set with the arrow keys( ). C:[current value]
It will be displayed on the bottom line. on/off
Laser Diode Test Diode On is displayed, when the laser diode is on. Ld On(Off)
On the other case Diode Off is displayed.
Laser Ready Test Laser Leady is displayed, When the Laser Laser Leady (Error)
Scanning Unit is ready to print. On the other case
Laser Error