4.4.1. HVPS(High Voltage Power Supply)
1) Transfer high voltage (THV (+))
- Function: It is a voltage that transfers toner on an OPC Drum to paper.
- Output voltage: MAX +4.2 KV +/- 5% (Duty is changeable, Not loading)
- 1.7KV +/- 15% (When cleaning, 200MOhm - It transfers toners with (+) polarity of transfer roller to an OPC Drum.
- Error type: IF THV (+) is not outputted, it causes a low density due to toner on an OPC Drum if it is not trans-
ferred to paper. It is possible that over-flow occurs if toner is piled up in a toner vessel continuously.
2) Charge voltage (MHV)
- Function: It is a voltage that charges a surface of OPC to -750V~-900V.
- Output voltage: -1.35KV~1.5KV DC +/- 50V
- Error type: IF MHV is not outputted, toner overflows and reaches to an OPC drum if surface of an OPC is not
charged. A black paper is printed out when it happens.
3) Cleaning voltage: THV (-)
- Function: It removes contamination at a rear by sending (-) polarity in a transfer roller to OPC drum to take toner.
- Output voltage: A change range is large according to a load because there is no feedback control =(-600V~-
1200V)
- Error type: An error due to contamination of toner on a backside of printing paper.
4) Developing voltage (DEV)
- Function: It is a voltage that develops toner with electronic potential difference of the section exposed by LSU
(Laser Scanning Unit).
* When printing, exposing voltage of OPC is -250V and exposing voltage of DEV is -470V. Therefore,
toner with (-) polarity is developed on an exposed section.
- Output voltage: -380V~500DC +/- 20V
- Error type: a) If DEV is GND, a density gets extremely low.
b) When DEV is floating due to instable of terminals contacting point, and etc., density gets
extremely high.
5) Supplying voltage (SUP)
- Function: It is a voltage that supplies toner to a developing roller.
- Output voltage: -560V~680V DC +/- 50V (Use AENER, Gearing of DEV - (-)180V more than DEV)
- Error type: a) When SUP is GND, density gets extremely low.
b) If SUP is floating due to instable of terminals contacting point, and etc., density gets extreme-
ly low that it is hard to catch up with eyes.
6) OPC Ground ZENER voltage
- Function: It is a voltage to prevent an image contamination under the condition of low temperature and low
humidity environment.
- When a set prints without an output voltage, -100V is maintained on OPC ground. (-100V ZENER diode is con-
nected to OPC ground)
- Error type: a) When ZENER diode is - 0V, there is no serious image problem in general environment, but
in low temperature and low humidity environment, it is possible that a contamination occur
on entire image
b) When ZENER diode is disconnected, a blank page is printed out. (It is the same case as
when a ZENER diode is disconnected to OPC ground.)