Gas Connection
This appliance must be installed and connected in accordance with installa-
tion regulations in force in the country in which the appliance is to be used.
This appliance is supplied to run on natural gas only and cannot be used on
any other type of gas without modication. Conversion for use on LPG and
other gases must only be undertaken by a qualied person.
Connection with a rigid pipe made from copper and with
screw-on mechanical connectors.
Make the connection directly to the end of the elbow tted on
the appliance.
Connection using exible undulated metal tube with
screw-on connectors. (Fig. A)
You can use a exible stainless steel pipe available from your
after sales service department.
Connection using exible tube with screw-on connectors.
(Fig.B)
These tubes must not exceed 2 meters in length and must be
accessible along their entire length.
A full operational test and a test for possible leakages must be carried out
by the tter after installation.
Access to the whole length of the connection hose must be possible and
the gas hose must be replaced before its use before the end of service life
(indicated on the hose)
Elbow
The gas inlet connection tting is 1/2 inch female thread.
Gas distributed by pipe ; natural gas, propane-air gas or butane-air gas
For your safety, you must choose from the three following connection option.
For the user’s safety, we advise the connection to be made
with a rigid pipe if this is possible, using a exible undulated
metal tube with scerw-on connectors (maximum length
2meters) (Fig.A)
For an existing installation, where it is not possible to t a
reinforced, braided, exible gas hose, the connection can be
made with a exible gas hose (maximum length 2meters),
with two clamps.
One on the connector, and the other on the pressure
regulator, and a gasket should be tted between the
connector and the hob’s elbow. (Fig.B)
Elbow
Gas supplied by tank or cylinder (butane/propane)
You can obtain the connector and the gasket from your After-Sales Service.
In France, you must use a tube or a pipe featuring the “NF Gaz” logo.
If the installation is difcult, unscrew the Elbow slightly and tighten it after
locating the Elbow.
Fig.A Fig.B
Fig.A
Fig.B
Gasket
Connector
Clamp
25
Electrical Connection
This appliance must be earthed.
This appliance is designed to be connected to a 220~240V, 50/60Hz AC electricity supply.
The wires in the mains lead are coloured in accordance with the following code ;
- Green/yellow = Earth
- Blue = Neutral
- Brown = Live
The wire which is coloured green and yellow must be connected
to the terminal which is marked with the letter E or by the earth
symbol.
WIRING DIAGRAM
1
2
3
4
5
6
N
L
N
L
N
L
MICRO SWITCHES
IGNITER
(INPUT: 220V 50~60HZ, OUTPUT: 15.25V)
BLUE TO NEUTRAL
GREEN & YELLOW TO EARTH
BROWN TO LIVE
GND
CONNECTOR
Ignition
Electrode
GND
GREEN TO EARTH