43
ELECTRICAL CONNECTION
Your hob is sold with a power cable (type
H05V2V2F - T90, cross-section 1 mm²) with
three conductors (phase + ground + neutral).
After-sales service reference: 77X3767
(6470.1516). It must be connected to a
220-240 V
~
monophase grid via a
standardised CEI 60083 electrical outlet with
phase + ground + neutral or or an all-pole cut-
off device with a minimum distance between
contact openings of 3.5 mm.
The plug of the electrical outlet must be
accessible after installation.
Warning
The safety wire (green-yellow) is
connected to the appliance's ground
terminal and must be connected to the
ground lead of the electrical set-up.
The fuse in your set-up must be
10 amperes.
If the power cable is damaged, it must be
replaced by a cable or a special kit
available from the manufacturer or its
After-Sales Service Department.
Tip
In order to easily locate the reference
information for your appliance, we
recommend that you note them on the
"After-Sales Service Department and
Customer Relations" page (this page also
explains to you where to find this
information on your appliance).
11 //
INSTALLING YOUR APPLIANCE
A
A
A
A
••
Place your hob in the opening of the support
cabinet, carefully pulling the table toward you.
Reposition the burner heads, burner covers
and pan supports on the hob.
Connect your hob to the gas supply (See
"Gas Connection" chapter) and to the power
supply (See "Electrical Connection" chapter).
If you wish, you can immobilise the hob using
the four mounting brackets delivered with a
screw
(Fig. 02)
to attach them to the four
corners of the housing.
YYoouu mmuusstt uussee tthhee
hhoolleess pprroovviiddeedd ffoorr tthhiiss ppuurrppoossee,, aaccccoorrddiinngg ttoo
tthhee ddiiaaggrraamm aabboovvee
(Fig. 01)
..
SSttoopp ssccrreewwiinngg wwhheenn tthhee mmoouunnttiinngg bbrraacckkeett
ssttaarrttss ttoo bbeeccoommee ddeeffoorrmmeedd..
DDoo nnoott uussee aa ssccrreewwddrriivveerr..
CC
AABBLLEE CCRROOSSSS
--
SSEECCTTIIOONN TTOO BBEE UUSSEEDD
Fig. 01
Fig. 02
Mounting brackets
Underside view
of the housing
••
TIPS FOR FLUSH MOUNTING
Mounting brackets
A
H05V2V2F - T90
cable
Cross-section of
conductors in mm²
Fuse
222200--224400 VV
~~
5500 HHzz
3 conductors,
including one
ground wire
1
10 A